IBM TotalStorage NAS Gateway 300 Model G27 Provides a Image

Powerful New Solution for LAN to SAN Access

    PDF format for online viewing or downloading    PostScript format for PS printers  

 

 

At a Glance

 

If you need flexibility in your IT infrastructures and help with exploding storage requirements, then you will appreciate the IBM TotalStorage™ Network Attached Storage (NAS) family.

New 5196 Model G27 Highlights

bulletDual-node, clustered model of the TotalStorage NAS Gateway 300 with two high-performance 2.4 GHz processors in each node (engine)
bulletSix PCI slots in each engine to accommodate multiple LAN and SAN connections, a management adapter, and tape backup adapters
bullet4.5 GB memory capacity
bulletBuilt-in SCSI LVD port for tape backup
bulletNew high-performance, single and dual-port 2 Gbit/s Fibre Channel Adapters
bulletChoice of four high-performance Ethernet adapters for LAN attachment, including the new 10/100/1000 Mbps Copper Accelerated Ethernet Adapter
bullet560-watt, redundant hot-swappable power supplies and hot-swappable system fans
bulletPreloaded operating system and application code

Overview

The NAS Gateway 300 is a specialized storage device that provides a NAS interface to Fibre Channel storage systems. The NAS Gateway 300 can be directly connected to Fibre Channel storage such as IBM's FAStT products, or into the storage area network (SAN) infrastructure to allow connectivity to multiple storage devices on a SAN. When connected into a SAN infrastructure, the NAS Gateway 300 enables IP clients to access data on the SAN, gain access to SAN-based applications, and leverage the SAN for storage capacity. The value of the NAS Gateway 300 in your network is further enhanced by its support of multiple file access protocols that can enable file sharing across dissimilar operating systems on the IP network.

New NAS Gateway 300 Model G27

The NAS Gateway 300, 5196 Model G27, a dual-node (dual engines) clustered system, offers many outstanding new features and options that can help enhance the performance of your network. The processor speed of the Model G27 is more than two times the speed of its predecessor model, the 5196 Model G26. The Model G27 contains dual processors in each engine for faster processing capability, and several memory options to fine-tune performance based on your applications. The Model G27 has six high-performance PCI slots in each engine to accommodate more LAN ports and other device connections. New, higher performance Fibre Channel and Ethernet adapters can help provide an increase in system throughput. The Model G27 has a built-in SCSI port for tape backup, and redundant hot-swappable power supplies for reliability and availability. The dual-node design of the Model G27 can provide failover protection in the event of an engine failure, as well as increased processing power, depending on the application.

Key Prerequisites

bulletA mandatory Fibre Channel adapter must be selected for SAN connections.
bulletA mandatory Ethernet adapter must be selected for LAN connections.
bulletEither a 1 GB or 2 GB additional memory option must be selected.
bulletCountry-specific power cords must be selected with each system.
bulletAn EIA rack is required for rack mounting.

Planned Availability Date

November 22, 2002

Description

The NAS Gateway 300 is a member of IBM's family of Network Attached Storage (NAS) products that also include the NAS 100, NAS 200, and NAS 300. The Gateway 300 can be connected directly to Fibre Channel storage systems, such as IBM's FAStT products, or can make the data and storage capacity of a storage area network (SAN) available to IP-connected end-user clients and servers by acting as a gateway between the Ethernet LAN and the Fibre Channel SAN.

The new NAS Gateway 300, 5196 Model G27 offers many outstanding features and options that can help enhance the performance of your network. The Model G27 is a dual-node (dual engines) clustered system with each engine contained in a 5U enclosure designed for mounting in a standard 19-inch EIA rack. This dual-node, clustered system is designed to provide failover protection in the event of a single node failure and, depending on the application, can provide higher performance levels compared to single node systems of similar design. The NAS Gateway 300 Model G27 engines have 6 PCI slots for the purpose of inserting adapters for connections to the Ethernet LAN, Fibre Channel, management adapter, and tape backup adapters. The Model G27 contains many hot new features that can increase its versatility, reliability, and availability in your network. Features such as 2 Gbit/s Fibre Channel Adapters and a 10/1000/1000 Accelerated Copper Ethernet Adapter help increase your network's throughput. A built-in SCSI LVD port for tape backup, Mirrored OS HDD feature for failover protection of the system HDD, redundant hot-swappable power supplies, and hot-swappable system fans, all help to make the Model G27 a hot performer for your network. The Model G27 comes with preloaded operating system and application code. For additional information, refer to the Preloaded Operating System and Application Code Functions section.

IBM NAS Gateway 300, Model G27 Configuration

NAS 5196 Model G27

bulletDual 5187-7RY NAS Engines (each contained in a 5U enclosure)
bulletClustered system design, failover protection
bulletDual 2.4 GHz Intel® Xeon Processors (each engine)
bulletSix PCI slots per engine for LAN and SAN connections, management adapter, and tape backup adapters
bulletBuilt-in SCSI LVD port for tape backup
bulletPreloaded tuned operating system, application code
bullet36.4 GB HDD — Standard (for operating system and application code) — Optional Mirrored OS HDD feature adds second 36.4 GB HDD
bullet512 MB memory — Standard (up to 4.5 GB memory total — at least 1 GB optional memory is mandatory option per engine)
bullet1-port 10/100/1000 Mbps Ethernet — Internodal connection (standard)
bulletOptional Fibre Channel Adapters — (one adapter per engine mandatory), (SAN or tape backup connections — single-port adapter), (Redundant SAN connections — dual-port adapter)
bullet1-port, 2 Gbit/s Fibre Channel Adapter
bullet2-port, 2 Gbit/s Fibre Channel Adapter
bulletOptional Ethernet Adapters — (one adapter mandatory per engine) (LAN connections)
bullet4-port 10/100 Mbps Adapter
bullet1-port Gigabit SX Adapter (fiber optic cable connection)
bullet1-port 10/100/1000 Mbps Copper Ethernet Adapter
bullet1-port 10/100/1000 Mbps Copper Accelerated Ethernet Adapter
bulletOptional SCSI Adapter (SCSI tape backup connections)
bulletSCSI LVD/SE Adapter adds second port for tape backup
bulletDual, 560-watt redundant, hot-swappable, auto-ranging power supplies (per engine)
bulletHot-swappable system fans

Optional Features

Gigabit Ethernet SX Adapter (#0006): The Gigabit Ethernet SX Adapter is designed to provide 1000Base-SX connectivity to a Gigabit Ethernet network for servers over a 50 or 62.5 micron multimode fiber optic link attached to its duplex SC connector. This adapter has a 1000 Mbps data rate and 32- or 64-bit PCI bus mastering architecture, enabling the highest Ethernet bandwidth available in an adapter. The adapter is compliant with IEEE 802.3z Ethernet and PCI 2.1 standards, supporting compatibility with existing Ethernet installations.

bulletMinimum: None.
bulletMaximum: Two per engine.
bulletPrerequisites: None.
bulletCorequisites: If installed in Model G27, must be installed in both engines.
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: Refer to the Limitations section.

Remote Supervisor Adapter (#0010): The Remote Supervisor Adapter, in conjunction with the Advanced System Management (ASM) processor that is integrated into the base planar board of the servers, allows you to connect via LAN or modem from virtually anywhere for extensive remote management of NAS 5196 Model G27. Remote connectivity and flexibility with LAN capability are provided by Ethernet connection. The Remote Supervisor Adapter is designed to enable more flexible management through a Web browser interface, in addition to ANSI terminal, Telnet, and Netfinity® Director. The remote management function provided via this adapter can be accomplished with one adapter installed in one 5196-G27 engine and a cable(s) (#0016) connecting the other remaining engine together. It can also be accomplished by installing the Remote Supervisor Adapter in each of the G27 engines and interconnecting them via a interconnecting cable (#0016). The Remote Supervisor Adapter provides its host engine with the following functions in addition to remote management:

bulletContinuous health monitoring and control
bulletServer status and operating system independent operation
bulletSystem and component Vital Product Data (VPD) information
bulletAdvanced Predictive Failure Analysis® (PFA)
bulletAutomated Server Restart (ASR)
bulletAutomatic notification and alerts
bulletEvent log — time-stamped, battery-backed, attachment to e-mail alerts
bulletRemote graphics console redirection over LAN
bulletIntegrated serial port, which can be dedicated to systems management or shared with the system
bulletLAN, serial, and ASM interconnect remote access
bulletPoint-to-Point (PPP) support
bulletSimple Network Management Protocol (SNMP) and e-mail alerts
bulletDomain Name System (DNS) and Dynamic Host Configuration Protocol (DHCP) support
bulletRemote power control
bulletWindows NT® blue screen capture
bulletRemote firmware update and access to critical server settings

If only one Remote Supervisor Adapter is used with multiple engines connected together, these additional functions would not be available to those engines without this adapter.

bulletMinimum: None.
bulletMaximum: One per engine.
bulletPrerequisites: None.
bulletCorequisites: If a Remote Supervisor Adapter is to be installed on one or both engines of a G27 system, then the Remote Supervisor Interconnect Cable (#0016) must be installed on one of the two engines in order to interconnect the management functions in the two engines of the G27 system.
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: This adapter must be installed in PCI slot #1 of the NAS engine. Refer to the Limitations section.

SCSI LVD/SE Adapter (#0013): The Ultra160 SCSI Adapter enables the attachment of the highest speed SCSI tape backup devices to the 5196 Model G27. With data transfer speeds up to 160 MB/sec and the inclusion of features like Disconnect/Reconnect, this adapter accommodates the fastest storage devices with ease. Overall system throughput is further enhanced by the use of bus mastering Direct Memory Access (DMA).

bulletMinimum: None.
bulletMaximum: One.
bulletPrerequisites: None.
bulletCorequisites: If installed in the Model G27, must be installed in both engines.
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: Refer to the Limitations section.

4-Port 10/100 Ethernet Adapter (#0015): This adapter is designed to provide four auto-negotiated 10/100 Mbps full-duplex ports. The adapter provides four ports of IEEE 802.3-compliant 100Base-TX and 10Base-T Ethernet connectivity over unshielded twisted pair links through four RJ-45 connectors. This adapter is "accelerated" — it provides much of the TCP/IP processing, reducing the processor load on the engine. This adapter has a 64-bit, 66 MHz PCI bus mastering architecture and offers outstanding performance with low server CPU utilization. The adapter provides half-duplex and full-duplex operation at both 10 Mbps and 100 Mbps for all ports. Auto-negotiation of speed and duplex mode facilitates the use of the adapter in shared or switched environments running at either speed.

bulletMinimum: None.
bulletMaximum: Two per engine.
bulletPrerequisites: None.
bulletCorequisites: If installed in Model G27, must be installed in both engines.
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: Refer to the Limitations section.

Remote Supervisor Adapter Interconnect Cable (#0016): Connects the Remote Supervisor Adapter installed in one 5196 NAS Engine to a second 5196 NAS Engine, extending remote monitoring and control facilities to that engine.

bulletMinimum: None
bulletMaximum: One per engine
bulletPrerequisites: None
bulletCorequisites: Remote Supervisor Adapter (#0010)
bulletCompatibility Conflicts: None
bulletCustomer Setup: Yes
bulletField Installable: Yes
bulletLimitations: One per NAS G27 system

1-Port 10/100/1000 Copper Ethernet Adapter (#0018): This adapter is designed to provide one auto-negotiated 10/100/1000 Mbps full-duplex port. The adapter provides one port of either IEEE 802.3 compliant 10Base-T, 100Base-TX, or 1000Base-T Ethernet connectivity over Category 5 or better, unshielded twisted pair wiring. The bus mastering architecture offers outstanding performance with low server CPU utilization. This adapter provides half-duplex and full-duplex operation at 10 Mbps, 100 Mbps, and 1000 Mbps. Auto-negotiation of speed and duplex mode facilitates the use of the adapter in shared or switched environments running at either speed.

bulletMinimum: None.
bulletMaximum: Two per engine.
bulletPrerequisites: None.
bulletCorequisites: If installed in Model G27, must be installed in both engines.
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: Refer to the Limitations section.

1 GB Memory Upgrade (#0301): This feature upgrades memory on the 5196-G27 engine (5187-7RY) planar board by adding 1 GB of Error Correcting (ECC) SDRAM in the form of two 512 MB DIMMs.

bulletMinimum: At least one of this feature or at least one of feature number 0302, 2 GB Memory Upgrade, is required for each engine.
bulletMaximum: Two per engine.
bulletPrerequisites: None.
bulletCorequisites: If installed in Model G27, must be installed in both engines.
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: Refer to the Limitations section.

2 GB Memory Upgrade (#0302): This feature upgrades memory on the 5196-G27 engine (5187-7RY) planar board by adding 2 GB of ECC SDRAM in the form of two 1 GB DIMMs.

bulletMinimum: At least one of this feature or, at least one feature number 0301, 1 GB Memory Upgrade is required for each engine.
bulletMaximum: Two per engine.
bulletPrerequisites: None.
bulletCorequisites: If installed in Model G27, must be installed in both engines.
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: Refer to the Limitations section.

Mirrored OS HDD-Plant Installed (#3121): The Mirrored OS HDD feature adds a second (redundant) 36.4 GB SCSI HDD to the Model G27 NAS Engine. The second disk contains a mirror image of the operating system and application code stored on the primary system HDD. In the event of a primary disk failure, failover to the redundant HDD can occur, enabling normal system operation to continue.

bulletMinimum: None.
bulletMaximum: One per engine.
bulletPrerequisites: None.
bulletCorequisites: None.
bulletCompatibility Conflicts: None.
bulletCustomer Setup: No.
bulletField Installable: No.
bulletLimitations: If installed in one node of the Model G27, feature number 3121 must be installed in both. This feature is mutually exclusive with feature number 3122.

Mirrored OS HDD-Field Installed (#3122): The Mirrored OS HDD feature adds a second (redundant) 36.4 GB SCSI HDD to the Model G27 NAS Engine. The second disk contains a mirror image of the operating system and application code stored on the primary system HDD. In the event of a primary disk failure, failover to the redundant HDD can occur, enabling normal system operation to continue.

bulletMinimum: None.
bulletMaximum: One per engine.
bulletPrerequisites: None.
bulletCorequisites: None
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: If installed in one node of the Model G27, feature number 3122 must be installed in both. This feature is mutually exclusive with feature number 3121.

36.4 GB 10K Ultra 160 SCSI Hot-Swap SL HDD (Spare) (#3131): This feature provides a spare 36.4 GB SCSI Hot-Swap HDD to be used as a replacement in the event of a failure to the engine's primary HDD or the HDD contained in the Mirrored OS HDD (#3121, #3122) features.

bulletMinimum: None.
bulletMaximum: 99.
bulletPrerequisites: None.
bulletCorequisites: None
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: None.

1-Port 10/100/1000 Copper Accelerated Ethernet Adapter (#3305): This accelerated Ethernet adapter can offload the majority of TCP/IP processing and is designed to provide one auto-negotiated 10/100/1000 Mbps full-duplex port. The adapter provides one port of either IEEE 802.3 compliant 10Base-T, 100Base-TX, or 1000Base-T Ethernet connectivity over Category 5 or better, unshielded twisted pair wiring. This adapter supports a 64-bit wide slot with bus speeds of 66 MHz. This adapter has a bus mastering architecture that offers outstanding performance with low server CPU utilization. The adapter provides half-duplex and full-duplex operation at 10 Mbps, 100 Mbps, and 1000 Mbps. Auto-negotiation of speed and duplex mode facilitates the use of the adapter in shared or switched environments running at either speed.

bulletMinimum: None.
bulletMaximum: Two per engine.
bulletPrerequisites: None.
bulletCorequisites: If installed in Model G27, must be installed in both engines.
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: Refer to the Limitations section.

1-Port Fibre Channel Adapter (#3705): The 1-Port Fibre Channel Adapter is designed to be an intelligent, DMA bus master adapter optimized for high throughput. It contains a powerful RISC processor, Fibre Channel protocol module with 2-Gb/sec transceivers, PCI local bus interface. The Fibre Channel Adapter has a duplex-type LC connector for attaching multimode fiber cable. The adapter supports multimode fiber optic cable lengths up to 500 meters.

Key features include:

bullet400 MB/sec full duplex data rate over Fibre Channel connections.
bulletPCI bus operation at 133 MHz.
bullet64-bit PCI bus interface support for:
bulletFCP-SCSI protocols
bulletFC-AL public loop profile (FL-PORT FABRIC LOGIN)
bulletPPP fabric connection (F-PORT FABRIC LOGIN)
bulletFibre Channel service class 3
bulletMinimum: None.
bulletMaximum: Two per engine.
bulletPrerequisites: None.
bulletCorequisites: If installed in Model G27, must be installed in both engines.
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: Refer to the Limitations section.

2-Port Fibre Channel Adapter (#3706): The 2-Port Fibre Channel Adapter is designed to be high-performance 64-bit, 133 MHz PCI adapter that has been optimized for high throughput. It contains a powerful RISC processor, Fibre Channel protocol module with 2-Gb/sec transceivers, PCI local bus interface. The adapter supports host data transfers up to 200 MB/sec per channel, 400 MB/sec full duplex per channel. The Fibre Channel Adapter has two duplex-type LC connectors for attaching multimode fiber optic cable. The adapter supports multimode fiber optic cable lengths up to 500 meters.

Key features include:

bullet400 MB/sec full duplex per channel data rate over Fibre Channel connections.
bulletPCI bus operation at 133 MHz.
bullet64-bit PCI bus interfaces.
bulletSupport for:
bulletFCP-SCSI protocols
bulletFC-AL public loop profile (FL-PORT FABRIC LOGIN)
bulletPPP fabric connection (F-PORT FABRIC LOGIN)
bulletFibre Channel service class 3
bulletMinimum: None.
bulletMaximum: One.
bulletPrerequisites: None.
bulletCorequisites: If installed in Model G27, must be installed in both engines.
bulletCompatibility Conflicts: None.
bulletCustomer Setup: Yes.
bulletField Installable: Yes.
bulletLimitations: Refer to the Limitations section.

Specify Features

Power Cords Summary for Feature Numbers 0101 — 0114: Each of these features provide two power cords for the 5196 Model G27 engines. Since each engine contains redundant power supplies, two power cords per engine is required. The power cords should be selected based on the country or region in which the system will be installed as described below. Power cord selection must be made during the initial order of the Model G27. The power cords are not orderable via MES.

bulletMinimum: One per engine
bulletMaximum: One per engine
bulletPrerequisites: 5196-G27 system
bulletCorequisites: None
bulletCompatibility Conflicts: None
bulletCustomer Setup: No
bulletField Installable: No
bulletLimitations: None

Power Cord (#0101): Provides two power cords for U.S. (Chicago), Canada, Mexico, Brazil, Costa Rica, Peru, Colombia, Ecuador, Venezuela, Bolivia, Panama, El Salvador, Honduras, Nicaragua, Dominican Republic, Guatemala, Taiwan, Saudi Arabia, Thailand, Philippines, Japan. Six feet (1.8 m), unshielded, rated 250 V/10 A. Attached plug (NEMA 5-15P) designed for 100-125 V ac input.

Power Cord (#0102): Provides two power cords for Brunei, China, Hong Kong, Macao, Malaysia, Singapore, Bahrain, Cyprus, Ghana, Iraq, Ireland, Jordan, Kenya, Kuwait, Libya, Malawi, Malta, Nigeria, Oman, Qatar, Sierra Leone, Somalia, Tanzania, Uganda, United Arab Emirates, UK, Yemen, Zambia. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (BS 1363/A) designed for 200-240 V ac input.

Power Cord (#0103): Provides two power cords for Australia, New Zealand. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (AS/NZS C112) designed for 200-240 V ac input.

Power Cord (#0104): Provides two power cords for Albania, Angola, Austria, Belarus, Belgium, Bosnia, Bulgaria, Croatia, Czechoslovakia, Egypt, Finland, France, Germany, Greece, Hungry, Macedonia, Mozambique, Netherlands, Norway, Poland, Portugal, Romania, Russia, Saudi Arabia, Slovakia, Slovenia, Spain, Sudan, Sweden, Syrian Arab, Indonesia, South Korea, Iceland, Iran, Kazakhstan, Lebanon, Luxembourg, Turkey, Ukraine, Yugoslavia, Zaire. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (CEE 7-VII) designed for 200-240 V ac input.

Power Cord (#0105): Provides two power cords for Denmark. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (DK2-5a) designed for 200-240 V ac input.

Power Cord (#0106): Provides two power cords for Pakistan, South Africa, Nambia, Swaziland, Zimbabwe, Bangladesh, Myanmar, Sri Lanka. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (SABS 164) designed for 200-240 V ac input.

Power Cord (#0107): Provides two power cords for Switzerland, Liechtenstein. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (1011-S2450 7) designed for 200-240 V ac input.

Power Cord (#0108): Provides two power cords for Chile, Italy, Ethiopia. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (CEI 23-16) designed for 200-240 V ac input.

Power Cord (#0109): Provides two power cords for Israel. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (SI 32) designed for 200-240 V ac input.

Power Cord (#0110): Provides two power cords for U.S., Bahamas, Barbados, Bolivia, Brazil, Costa Rica, Dominican Republic, El Salvador, Ecuador, Guatemala, Guyana, Haiti, Honduras, Jamaica, N. Antilles, Panama, Peru, Trinidad, Venezuela, Liberia, Japan, Philippines, Taiwan, Thailand. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (NEMA 6-15P) designed for 200-240 V ac input.

Power Cord (#0111): Provides two power cords for Argentina, Uruguay, Paraguay. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (IRSM 2073) designed for 200-240 V ac input.

(#0112) Power Cord (#0112): Provides two power cords for China. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (GB 2099.1) designed for 200-240 V ac input.

Power Cord (#0113): Provides two power cords for equipment that will be mounted in IBM racks. Nine feet, (2.8 m), unshielded, rated 250/10 A. Attached plug (IEC 320 C14) designed to be plugged into IBM Power Distribution Units (PDUs) in IBM rack enclosures.

Power Cord (#0114): Provides two power cords for U.S., Bahamas, Barbados, Bolivia, Brazil, Costa Rica, Dominican Republic, El Salvador, Ecuador, Guatemala, Guyana, Haiti, Honduras, Jamaica, N. Antilles, Panama, Peru, Trinidad, Venezuela, Liberia, Japan, Philippines, Taiwan, Thailand. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (NEMA 5-15P) designed for 100-125 V ac input.

Preload Operating System for 5196-G27 (#0252): Preloads the operating system and other code load for the 5196-G27.

bulletMinimum: One per engine
bulletMaximum: One per engine
bulletPrerequisites: 5196-G27 system
bulletCorequisites: None
bulletCompatibility Conflicts: None
bulletCustomer Setup: No
bulletField Installable: No
bulletLimitations: None

Pubs Group for 5196-G27 (#0701): Provides system documentation on CD-ROM, hardcopy safety manual, installation instructions for 5196-G27 system.

bulletMinimum: One per 5196-G27 system
bulletMaximum: One per 5196-G27 system
bulletPrerequisites: 5196-G27 system
bulletCorequisites: None
bulletCompatibility Conflicts: None
bulletCustomer Setup: No
bulletField Installable: No
bulletLimitations: None

Accessibility by People with Disabilities

For Hardware Offerings:

The following features support use by people with disabilities:

bulletControls and latches are operable with one hand and minimal dexterity.
bulletKeys are discernible by touch without activating them.
bulletPorts and connectors support connection of industry-standard devices.

Product Positioning

The IBM TotalStorage NAS family of products are modular, network storage products designed to provide businesses with solutions for the ever-changing storage requirements prevalent in today's business climate.

The NAS Gateway 300, 5196 Model G27, a member of the IBM NAS family, is a dual-node, specialized NAS server that is positioned in the network between the Ethernet LAN and the SAN. It is designed to appear as a typical NAS device to servers and end-user clients. The NAS Gateway 300 is LAN attached to end-user clients, computers, as well as file, application, and transaction servers. The dual-node 5196 Model G27 is attached to the SAN via high-speed 2 Gbit/s Fibre Channel, providing a high-performance path for servers and end-user clients to gain access to the vast storage resources located on the SAN. The 5196 Model G27 is a key building block to be considered when planning the infrastructure that provides access to the SAN.

Reference Information

bulletHardware Announcement 101-046 , dated February 21, 2001, entitled IBM TotalStorage Network Attached Storage 300G, 5196 Models G00, G25 Provides High Performance Specialized Server Between Your LAN and SAN
bulletHardware Announcement 101-323 , dated October 30, 2001, entitled IBM TotalStorage Network Attached Storage 300G Enhancements — New Models and Features Provide Enhanced Performance and Flexibility

Trademarks

 
TotalStorage is a trademark of International Business Machines Corporation in the United States or other countries or both.
 
Netfinity and Predictive Failure Analysis are registered trademarks of International Business Machines Corporation in the United States or other countries or both.
 
Intel is a registered trademark of Intel Corporation.
 
Windows NT is a registered trademark of Microsoft Corporation.
 
Other company, product, and service names may be trademarks or service marks of others.

IBM TotalStorage™ NAS Gateway 300

NAS Gateway 300, 5196 Model G27

Image

Preloaded Operating System and Application Code Functions

Windows® Powered OS (SP2®)

bulletOptimized for NAS Gateway 300 Model G27

Server Appliance Kit (SAK) Features

bulletStorage Manager for SAK V2
bulletUninterruptible Power Supply (UPS) Agent

Clustered Systems

bulletDomainlet — (5196 Model G27)

File Systems Supported

bulletCIFS (Windows NT® LM 0.12), NFS (V2, V3), FTP, HTTP (V1.1), Apple File protocol, NetWare (via Windows Services for NetWare V5)

Setup Tutorial

bulletNAS Setup Navigator

Remote NAS System Administration

bulletAdministrative task performed in the Web-based GUI
bulletIBM Advanced Appliance Configuration Utility
bulletAlternate administrative task performed using Windows Terminal Service
bulletAdvanced management functions available via Windows Terminal Service
bulletSimple point-and-click for restores using Windows NT Backup
bulletNAS Backup Assistant MMC Snap-in Web page

UNIX® Services

bulletNFS support
bulletWeb-based GUI for performing administrative tasks
bulletMicrosoft™ Services for UNIX V2.2+QFE
bulletNFS V2 (IETF RFC 1084), V3 (IETF RFC 1830)

Simple Network Management (SNMP) Enabled

bulletProvides the capability of the NAS Gateway 300 to be managed by a network management application, such as IBM Director using SNMP protocols

Automatic Recovery of Operating System

bulletCustomer-scheduled backups of the system partition
bulletOriginal factory CD-ROM reload of operating system
bulletPrevention of accidental reloads via reload enablement diskette

Advanced Aggregate Management

bulletIBM Director Agent V3.11

Columbia Data Products' Persistent Storage Manager (PSM) for IBM NAS Products — V2.2

PSM creates True Images (multiple point-in-time persistent images of any or all system data volumes). All persistent images are designed to survive system power loss or a planned or unplanned re-boot. Each instance of PSM is designed to handle 250 concurrent data images. Typically, any image can be easily managed through the Microsoft Web user interface, and accessed the same as any other active volume. In case of data corruption or loss, typically, any persistent image can be used for instant restoration of the entire volume from the image, which can help substantially reduce the amount of system down time.

PSM is designed to:

bulletCreate and keep multiple point-in-time persistent images
bulletProvide clustered node support
bulletFailover of an original volume along with all of its persistent images to a surviving clustered node
bulletRestore one or more volumes from persistent images instantly (typically within seconds)
bulletAdministrators can use this function to restore larger amounts of data in lieu of restoring files one by one.
bulletEnable user-level file retrieval
bulletUser-level access can be granted for one or more of the images to allow users to retrieve older copies of their own files from the images. Users will automatically have the same access privileges to individual files and directories in the images that they would have on the live volume.
bulletProvide flexible and configurable image access and administration via Web-based user interface
bulletSchedule images (for each schedule entry [image group], specify interval, number to keep, image name, properties [read-only or read-write, retention level])
bulletCreate a new image immediately (specify name and properties)
bulletDelete images
bulletView and change properties of images (also reset read-write images)
bulletRestore a volume (from any image of that volume)
bulletConfigure advanced parameters
bulletMaximum number of images to keep concurrently
bulletName of image root directory (all images on a volume are mounted as junctions, for example, virtual volumes) under the image root directory
bulletInactive period and inactive period wait timeout
bulletSize of the image cache file (per volume)
bulletImage cache file usage warning and automatic image deletion thresholds (per volume)

IBM Director with Universal Manageability (UM) Services V3.11

The NAS Gateway 300 system preloaded code contains IBM Director Agent V3.11. This provides the Gateway 300 with a client management application for networked computers, helping centralize control of your computer systems and lower the total cost of management. The IBM Director Agent is designed to allow the user to view, monitor, and control the NAS Gateway 300 through a management application such as the IBM Director/Server. UM Services is one of the Universal Manageability solutions from IBM. UM Services is also intended to allow you to:

bulletLearn detailed inventory information about the NAS Gateway 300, including operating system, memory, network adapters, and other hardware
bulletTrack the NAS Gateway 300 proactively with features such as power management, event log, and system monitor capability
bulletUpwardly integrate with Tivoli® Enterprise, Tivoli NetView®, Computer Associates Unicenter, HP OpenView, Microsoft SMS, and Intel® LANDesk™ Management Suite

Because UM Services use some of the latest systems management standards, including Common Information Model (CIM), Web-Based Enterprise Management (WBEM), and the eXtensible Markup Language (XML), management of the NAS Gateway 300 can typically be integrated with most enterprise management environments.

The IBM Director/Server is designed to provide the additional management functions that can be used to aid in managing the Gateway 300, such as Advanced Systems Management, Capacity Manager, Cluster Systems Management, Fibre Channel Storage, IBM Rack Manager, and ServeRAID™ Manager.

Tivoli Storage Manager (TSM) V4.2.2

The IBM NAS Gateway 300 comes with the TSM Agent and Client V4.2.2 software pre-installed and ready to license to allow backup of the Gateway 300 data to a TSM server. This backup client is designed to provide file level backup and restore functionality.

TSM is designed to be a full-function storage software solution that addresses the challenges of complex storage management across a distributed environment. It can manage a broad range of data storage, recovery, and availability functions across your entire computing infrastructure, from the massive enterprise file servers in your data center to the storage peripherals throughout your organization and to the laptops in your remote offices.

TSM is designed to enable organizations with large amounts of mission-critical data held on distributed heterogeneous platforms to interface with up to seven different platforms, including Windows 2000, Sun Solaris, HP-UX, AIX®, OS/390®, VM, and OS/400®. For additional information on TSM, refer to the following Web site:

http://www.tivoli.com/storage

Tivoli SANergy™ V2.2.3

Tivoli SANergy software is pre-installed and ready to license on the TotalStorage NAS Gateway 300 to enable two different solution offerings that are designed to provide the benefits of a NAS device with the higher performance and scalability of a SAN.

For customers using the NAS Gateway 300 as a Web or FTP server, multiple Gateway 300s can be connected to the same storage to provide increased I/O to the same files on SAN storage. By connecting more Gateway 300s to the SAN, IT administrators can accommodate increasing numbers of HTTP or FTP requests for the same data on the SAN by clients across the LAN.

Similarly, for individual computers requiring higher bandwidth access to the SAN storage than any LAN connection can provide, the pre-installed Tivoli SANergy is also ready to license and use.

Many computers connected to the NAS Gateway 300 can have higher bandwidth access to SAN storage by purchasing another license for Tivoli SANergy software and adding a Fibre Channel host bus adapter. With these two pieces and a direct SAN connection to the NAS Gateway 300's Fibre Channel storage, these bandwidth-hungry computers can receive data from the NAS Gateway 300 at up to 100 MB per second. Tivoli SANergy is designed to dynamically route data to either the LAN or SAN to provide optimum network utilization.

These simple steps not only increase disk to computer bandwidth for individual computers, but also help reduce CPU utilization on those computers while accessing SAN storage; reduce data copy and transfer times between any computer connected this same way; and reduce traffic over the LAN. For more information on Tivoli SANergy, contact Tivoli, or refer to:

http://www.tivoli.com/products/index/sanergy

Domainlet

The Domainlet feature allows for a subset of the full domain function to be implemented on the clustered NAS Engines rather than in a separate Domain Controller server. This feature will enable the creation of a new "Domain" that encompasses just the cluster itself and exists only to provide authentication and authorization for the cluster service and any other installed services for the Model G27 supporting the cluster feature. The second node in the cluster will be a replica to the new "Domainlet" and will contain well-known policies and groups, such as administrators, domain administrators, and the service accounts required by the clusters it supports, but nothing else. The "Domainlet" configuration is subject to the following license restriction: This NAS product is not licensed to provide full domain controller function, but may be used as a "Domainlet" to the limited extent necessary to form a server cluster and authenticate users accessing resources on this NAS server cluster where:

  1. Active Directory is configured as a single forest containing a single domain comprised of two and only two NAS nodes (the Domain )
  2. No other domains, domain controllers, or servers of any type are allowed to join this Domain
  3. No domains of any type are allowed to trust this Domain

    (For additional information, refer to the End User License Agreement that is included with the NAS product.)

The function included in this release eliminates the need for a separate, external Windows-based "Domain Controller" for the formation of the cluster in a UNIX-only environment, which may not have this function available.

Services for UNIX V2.2+QFE

Services for UNIX V2.2+QFE can support enhanced performance for NFS V2.

Services for NetWare V5 (SFN5)

This release incorporates Windows SFN5 as the means to provide interoperability within the Novell environment. SFN5 provides a complete set of new interoperability services and tools for integrating the Windows 2000-based servers into existing NetWare environments.

Only NetWare V5 Print and File services are included in the preloaded code and is required for supporting NetWare File system protocol. Since the NAS emulates a NetWare file server including the NetWare UI, individual NetWare users, and/or servers can access the NAS as if it were another NetWare server. Clustering is not supported by the SFN5.

Storage Manager for SAK V2

This release of the preloaded code includes Storage Manager for SAK V2, a storage management tool that includes the following functions:

bulletStorage Reports
bulletDirectory Quotas
bulletFile Screening

Storage Reports address disk usage, wasted storage space, file ownership, security, and administration. Reports can run interactively, scheduled on a regular basis, or run as part of a storage resource management policy when disk space utilization reaches a critical level.

Directory Quotas allows the administrator to add, delete, monitor, and change disk space limits for selected directories on the NAS appliance.

Directory Quotas provide disk space monitoring and control in real time, and support active and passive limits with two real-time space alarms.

File Screening allows the blocking of any file type such as MP3, graphics files, VBS viruses, and executables from writing to the NAS appliance.

NAS Setup Navigator

The NAS Setup Navigator provides a GUI that guides the user through the steps required to initially configure the IBM NAS products. The tasks that need to be performed are displayed in a two-level menu tree on the left side of the screen. When the user selects a task, the right side of the screen displays a brief description of that task. In many cases, a content window will also contain a description of where to get more detailed information. The basic configuration tasks described are:

bulletGeneral Settings: Administrator user ID and password, date/time, network identification, system language
bulletLAN Network Settings: Public and private connections
bulletRAID Setup, Shares: NFS, CIFS
bulletServices for UNIX: NFS server and gateway, NIS server, user name mapping, password synchronization, server for PCNFS
bulletUsers/Groups, Clustering Setup: Two-node, using a Domainlet
bulletCluster Administration: Cluster properties, disk group administration, resource balancing, file sharing

Uninterruptible Power Supply (UPS) Agent

The preloaded code includes a UPS agent to receive power failure notifications from an external UPS product.

An external UPS unit may be added to provide emergency backup power for a specific period of time when the local power fails. This power comes from batteries housed within the UPS. During a power failure, the UPS is designed to instantly switch your server appliance to emergency battery backup power. The UPS agent enables you to control how the UPS service works on your server appliance. The available UPS settings depend on the specific UPS hardware used on your system. You will need to configure the following information:

bulletUPS device manufacturer
bulletUPS device model
bulletThe serial port to which the UPS device is connected

Ethernet Teaming Considerations for the Gateway 300 Model G27: Teaming/load balancing is a method of combining several Ethernet link level connections to form a single logical IP network connection. The NAS Gateway 300 Model G27 offers a choice of four Ethernet adapters that plug into the PCI slots in the G27 engines and provide connections to the Ethernet LAN. These adapters, within certain limitations, can help implement teaming on the Model G27. Refer to the product publication IBM TotalStorage NAS Gateway 300 User's Reference , GA27-4321, for greater detail.

Ethernet Adapters Available for the Model G27

bullet1-port Gigabit Ethernet SX Adapter (#0006)
bullet4-port 10/100 Mbps Ethernet Adapter (#0015)
bullet1-port 10/100/1000 Mbps Copper Ethernet Adapter (#0018)
bullet1-port 10/100/1000 Mbps Copper Accelerated Ethernet Adapter (#3305)

Valid teaming combinations are:

bulletGigabit Ethernet SX Adapter (#0006) with another Adapter (#0006)
bulletGigabit Ethernet SX Adapter (#0006) with a 10/100/1000 Copper Ethernet Adapter (#0018)
bullet10/100/1000 Copper Ethernet Adapter (#0018) with another Ethernet Adapter (#0018)
bulletAny combination of ports on a single 4-port 10/100 Ethernet Adapter (#0015)
bulletAny combination of up to four ports between two 4-port 10/100 Ethernet Adapters (#0015)
bullet10/100/1000 Copper Accelerated Ethernet Adapter (#3305) with another Accelerated Ethernet Adapter (#3305) (using only Gig EtherChannel [GEC] or IEEE 802.3ad modes)

Teaming Adapters (#0006 and #0018)

The Gigabit Ethernet SX Adapter (#0006) and 10/100/1000 Copper Ethernet Adapter (#0018) can implement teaming using the following modes:

bulletAdapter Fault Tolerance (AFT)
bulletSwitch Fault Tolerance (SFT)
bulletAdaptive Load Balancing (ALB)
bulletCisco Fast EtherChannel (FEC) and GEC
bulletIEEE 802.3ad Link Aggregation Group Specification

Teaming Adapters (#0015 and #3305)

The 4-port 10/100 Ethernet Adapter (#0015) and the 10/100/1000 Copper Accelerated Ethernet (#3305) use Session-Layer Interface Card (SLIC) technology which incorporates hardware assist for TCP processing. This acceleration will only be supported simultaneously with teaming if all of the ports are on the same adapter. These adapters can implement teaming/load balancing using the following modes:

bulletCisco FEC and GEC
bulletIEEE 802.3ad Link Aggregation Group Specification
bulletOutbound-Only Teaming
bulletHot Standby Failover

Publications

The following publications are shipped with the product. The Installation Guide, Quick Start Instructions, and Release Notes are shipped in hardcopy, and all documentation (except the Release Notes) is included in PDF and HTML format on the documentation CD-ROM.

                                                  Order
Title                                             Number

IBM TotalStorage NAS 100,                         GA27-4319
 200, and Gateway 300
 Planning Guide

IBM TotalStorage                                  NA
 NAS Gateway 300
 Quick Start Instructions

IBM TotalStorage                                  GA27-4320
 NAS Gateway 300
 Hardware Installation Guide

IBM TotalStorage                                  GA27-4321
 NAS Gateway 300
 User's Reference

IBM TotalStorage                                  GY27-0414
 NAS Gateway 300
 Hardware Service Guide

IBM TotalStorage                                  NA
 NAS Gateway 300
 Documentation CD

IBM TotalStorage                                  NA
 NAS Gateway 300
 Release Notes

IBM TotalStorage NAS                              GA27-0043
 Translated Safety
 Notices

NA = Not Applicable

All of the publications contained on the CD-ROM are also available on the Web in PDF format at:

http://www.ibm.com/storage/support/nas

Technical Information

Specified Operating Environment

Physical Specifications: Per NAS Engine

bulletWidth: 440 mm (17.3 in)
bulletDepth: 674 mm (26.5 in)
bulletHeight: 216 mm (8.5 in)

 

bulletWeight — Minimum configuration (approximate): 67 kg (148 lb)

 

bulletWeight — Maximum configuration (approximate): 91.6 kg (202 lb)

Standards

EMC

The product conforms to the following EMC standards:

bulletFCC Class A
bulletCISPR-22 Class A
bulletVCCI Class 1
bulletBSMI Class A

Safety

The product conforms to the following safety standards:

bulletUL 1950 (U.S.)
bulletCSA C22.2 No.950 (Canada)
bulletTUV/CDE/IEC950/EN60950 (EU,Germany)
bulletNOPM-018 (Mexico)
bulletCE Mark (EU)
bulletCB Certificate (EU)
bulletGOST-R (Russia)
bulletBSMI Type Certification (Taiwan)

Operating Environment

Temperature (operating)

bullet10° to 35°C (50° to 95°F) at 0-914 m (0-3000 ft)
bullet10° to 32°C (50° to 90°F) at 914 — 2,133 m (3,000-7,000 ft)

Temperature (storage)

bullet-40° to 60°C (-40° to 140°F) at 0 — 2,133 m (0-7,000 ft)

Relative Humidity (operating and storage)

bullet8-80%

Wet Bulb

bulletWet Bulb (operating temperature): 23°C
bulletWet Bulb (storage temperature): 27°C

Electrical Power (per NAS Engine)

bulletInput voltage low range (90-137 V ac, 50-60 Hz)
bulletInput voltage high range (180-265 V ac, 50-60 Hz)
bulletInput kilovolt-amperes (kVA) (0.8 kVA)

Noise Level 

bullet6.3 bels — Horizontal floor standing position (operating)

Note: The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random sample of machines. All measurements made in accordance with ISO 7779 and reported in conformance with ISO 9296.

Hardware Requirements

Power Cord Requirement

One of the following Power (Line) Cord features must be specified for NAS Gateway 300, 5196 Model G27 for the correct country-specific power cord to ship with the machine(s).

bulletFeature number 0101 — Power Cord (#1) U.S. Six Foot (1.8 m), 125 V. Provides power cords for U.S., Canada, Mexico, others. Six feet (1.8 M), unshielded, rated 250 V/10 A. Attached plug (NEMA 5-15P) is designed for 100-125 V ac input.
bulletFeature number 0102 — Power Cord (#2) Europe, Middle East, Africa. Provides power cords for Brunei, China, China (Hong Kong S.A.R), Macao, Malaysia, Singapore, Bahrain, Cyprus, Ghana, Iraq, Ireland, Jordan, Kenya, Kuwait, Libya, Malawi, Malta, Nigeria, Oman, Qatar, Sierra Leone, Somalia, Tanzania, Uganda, United Arab Emirates, UK, Yemen, Zambia. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (BS 1363/A) is designed for 200-240 V ac input.
bulletFeature number 0103 — Power Cord (#3) Australia, New Zealand. Provides power cords for Australia, New Zealand. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (AS/NZS C112) is designed for 200-240 V ac input.
bulletFeature number 0104 — Power Cord (#4) Europe, South Korea. Provides power cords for Albania, Angola, Austria, Belarus, Belgium, Bosnia, Bulgaria, Croatia, Czechoslovakia, Egypt, Finland, France, Germany, Greece, Hungry, Macedonia, Mozambique, Netherlands, Norway, Poland, Portugal, Romania, Russia, Saudi Arabia, Slovakia, Slovenia, Spain, Sudan, Sweden, Syrian Arab, Indonesia, South Korea, Iceland, Iran, Kazakhstan, Lebanon, Luxembourg, Turkey, Ukraine, Yugoslavia, Zaire. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (CEE 7-VII) is designed for 200-240 V ac input.
bulletFeature number 0105 — Power Cord (#5) Europe, Denmark. Provides power cords for Denmark. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (DK2-5a) is designed for 200-240 V ac input.
bulletFeature number 0106 — Power Cord (#6) Pakistan, South Africa. Provides power cords for India, Pakistan, South Africa, Nambia, Swaziland, Zimbabwe, Bangladesh, Myanmar, Sri Lanka. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (SABS 164) is designed for 200-240 V ac input.
bulletFeature number 0107 — Power Cord (#7) Switzerland, Liechtenstein. Provides power cords for Switzerland, Liechtenstein. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (1011-S2450 7) is designed for 200-240 V ac input.
bulletFeature number 0108 — Power Cord (#8) Chile, Italy, Ethiopia. Provides power cords for Chile, Italy, Ethiopia. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (CEI 23-16) is designed for 200-240 V ac input.
bulletFeature number 0109 — Power Cord (#9) Israel. Provides power cords for Israel. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (SI 32) is designed for 200-240 V ac input.
bulletFeature number 0110 — Power Cord (#10) U.S., Japan, South America — 240 V. Provides power cords for U.S., Bahamas, Barbados, Bolivia, Brazil, Costa Rica, Dominican Republic, El Salvador, Ecuador, Guatemala, Guyana, Haiti, Honduras, Jamaica, N. Antilles, Panama, Peru, Trinidad Venezuela, Liberia, Japan, Philippines, Taiwan, Thailand. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (NEMA 6-15P) is designed for 200-240 V ac input.
bulletFeature number 0111 — Power Cord (#11) Argentina. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (IRSM 2073)is designed for 200-240 V ac input.
bulletFeature number 0112 — Power Cord (#12) China. Nine feet (2.8 m), unshielded, rated 250 V/6 A. Attached plug (GB 2099.1) is designed for 200-240 V ac input.
bulletFeature number 0113 — Power Cord (#13) Universal Jumper Cable. Provides power cords for equipment that will be mounted in IBM racks. Attached plug is designed to be plugged into IBM Power Distribution Units (PDU) in IBM rack enclosures. Nine feet (2.8 m), unshielded, rated 250 V/10 A. Attached plug (IEC 320 C14) is designed for 200-240 V ac input.
bulletFeature number 0114 — Power Cord (#14) U.S. Nine Foot (2.8 m). Provides power cords for U.S., Bahamas, Barbados, Bolivia, Brazil, Costa Rica, Dominican Republic, El Salvador, Ecuador, Guatemala, Guyana, Haiti, Honduras, Jamaica, N. Antilles, Panama, Peru, Trinidad, Venezuela, Liberia, Japan, Philippines, Taiwan, Thailand. Nine feet (2.8 m), unshielded, rated 125 V/10 A. Attached plug (NEMA 5-15P) is designed for 100-120 V ac input.

System Mounting Requirement

The NAS Gateway 300 Model G27 is designed to be rack-mounted in an EIA industry-standard rack. The Model G27 requires 10U of rack space.

System Memory Requirement

The NAS Gateway 300 Model G27 comes with 512 MB of double data rate (DDR) synchronous DRAM (SDRAM) in the form of two 256 MB memory modules on the system planar board. The Model G27 memory contains error correcting code (ECC). The 512 MB memory occupies two the six memory slots on the planar board. The engines have a supported memory capacity of 4.5 GB and can be upgraded by plugging 512 MB or 1 GB pairs of memory modules into the four remaining, unpopulated memory slots on the planar board. This allows upgrading memory in 1 GB or 2 GB increments.

Note: Upgrading to the 4.5 GB maximum can only be accomplished by installing two, 2 GB memory features.

A mandatory memory upgrade of at least 1 GB of additional memory per engine is required.

Ethernet and Fibre Channel Adapter Requirements

The NAS Gateway 300 connects to servers and end-user clients via the Ethernet LAN. The Model G27 has an integrated 1-port 10/100/1000 Mbps adapter on the planar board of each engine, but is used for internodal communications, and cannot be used for customer connections to the Ethernet LAN.

An optional 4-port 10/100 Mbps, Gigabit SX, 10/100/1000 Mbps Copper, or 10/100/1000 Mbps Copper Accelerated Ethernet adapter is required to attach the dual-node Model G27 to the Ethernet LAN. At least one Ethernet adapter must be installed in each engine.

The 5196 Model G27 attaches to the SAN via optional Fibre Channel adapters that plug into the optional adapter slots. Single- and dual-port adapters are available for the G27. At least one Fibre Channel adapter must be installed in each engine.

Software Requirements

The NAS Gateway 300 is shipped containing preloaded code. No additional code is required and no programs other than those shipped with the system and those tested and demonstrated to be compatible with the Gateway 300 should be loaded or executed on this product.

Compatibility: IBM continues to perform ongoing interoperability testing on current and new IBM and third-party products. Refer to the following IBM Web sites for the most current and up-to-date IBM TotalStorage NAS interoperable listings:

http://www.storage.ibm.com/snetwork/nas/nas_interoperability.html

http://www.storage.ibm.com/proven/index.html

Compatibility with Multi-Path Failover Support

Multi-path failover support is designed to allow the NAS Gateway 300 to continue assessing storage on its attached device(s) even if an element in the path (for example, adapter, cable, or switch) fails. The software within the storage device can automatically seek an alternate path to the Gateway 300 and the Gateway can recognize and support this change in path.

bulletSupport for IBM Enterprise Storage System via Storage Sub-system Device Driver
bulletSupport for IBM FAStT 200, 500, and 700 via RDAC support

Limitations

Optional Adapter Features for NAS Gateway 300, 5196 Model G27

Each 5196 Model G27 engine has six PCI slots available for purposes of installing optional features. A combination of up to six of the features below may be installed in each engine, in accordance with the maximum number for each type of adapter per engine as shown.

                                               Maximum Number of
                                  Feature      Optional Adapters
Adapter Name                      Number       Per Engine

1-port Fibre                      3705         2  Notes 1, 5, 6, 7, 8
 Channel Adapter

2-port Fibre                      3706         1  Notes 1, 4, 5, 6, 7
 Channel Adapter

4-port 10/100                     0015         2  Notes 2, 3, 5, 7, 9
 Mbps Ethernet
 Adapter

10/100/1000 Mbps                  0018         2  Notes 2, 3, 5, 7, 9
 Copper Ethernet
 Adapter

10/100/1000 Mbps                  3305         2  Notes 2, 3, 5, 7, 9
 Copper Ethernet
 Accelerated
 Adapter

                                               Maximum Number of
                                  Feature      Optional Adapters
Adapter Name                      Number       Per Engine

Gigabit SX                        0006         2  Notes 2, 3, 5, 7, 9
 Ethernet
 Adapter

SCSI LVD/SE                       0013         1  Notes 5, 6, 7, 8
 Adapter (Tape
 Backup feature)

Remote                            0010         1  Notes 5, 10
 Supervisor
 Adapter

Note 1: The 5196 Model G27 must have a minimum of one optional Fibre Channel Adapter installed in each engine for connection to the SAN, either a 1-port or 2-port adapter.

Note 2: The 5196 Model G27 must have a minimum of one optional Ethernet Adapter installed in each engine, either 4-port 10/100 Mbps, Gigabit Ethernet SX, 10/100/1000 Mbps Copper, or 10/100/1000 Mbps Copper Accelerated Adapter for connections to the Ethernet LAN.

Note 3: The maximum total quantity of the combination of the 4-port 10/100 Mbps Ethernet, 10/100/1000 Mbps Copper Ethernet, 10/100/1000 Copper Accelerated Ethernet, and Gigabit SX Ethernet cannot exceed 4.

Note 4: The 2-port Fibre Channel Adapter, if installed, must be installed in slot number 6 only.

Note 5: The maximum total quantity of PCI adapters features, in all supported combinations, cannot exceed 6.

Note 6: If the 2-port Fibre Channel Adapter is installed, then only one of either the 1-port Fibre Channel Adapter or the SCSI LVD/SE Adapter can be installed, but not both.

Note 7: The maximum total quantity of the combination of the 1-port Fibre Channel Adapter, 2-port Fibre Channel Adapter, 4-port 10/100 Ethernet Adapter, Gigabit SX Ethernet Adapter, 10/100/1000 Copper Ethernet Adapter, 10/100/1000 Copper Accelerated Ethernet Adapter, and SCSI LVD/SE Adapter cannot exceed 5.

Note 8: If two , 1-Port Fibre Channel Adapters are installed, they are mutually exclusive with the SCSI LVD/SE Adapter.

Note 9: If the combination of the 1-port Fibre Channel Adapter, 2-port Fibre Channel Adapter, and SCSI LVD/SE Adapter equals 2, then the maximum total quantity of the combination of the 4-port 10/100 Mbps Ethernet, 10/100/1000 Mbps Copper Ethernet, 10/100/1000 Copper Accelerated Ethernet, and Gigabit SX Ethernet cannot exceed 3.

Note 10: The Remote Supervisor Adapter must be installed in Slot Number 1 only.

Features Installed in 5196 Model G27

For the 5196-G27, if any of the following features are to be installed, the feature must be installed in both nodes (NAS Engines) and have the same quantity and type.

bullet1-port Fibre Channel Adapter (#3705)
bullet2-port Fibre Channel Adapter (#3706)
bulletSCSI LVD/SE Adapter (#0013)
bullet4-port 10/100 Ethernet Adapter (#0015)
bulletGigabit SX Ethernet Adapter (#0006)
bullet10/100/1000 Copper Ethernet Adapter (#0018)
bullet10/100/1000 Copper Accelerated Ethernet Adapter (#3305)
bulletMirrored OS HDD (#3121 — Plant Installed)
bulletMirrored OS HDD (#3122 — Field Installed)
bullet1 GB Memory Upgrade (#0301)
bullet2 GB Memory Upgrade (#0302)

Example 1: If one node has two 4-port 10/100 Mbps Ethernet Adapters, and one 2-port Fibre Channel Adapter, the other node must have identical adapters.

Example 2: If one node has one Gigabit Ethernet SX Adapter, and two 1-port Fibre Channel Adapters, the other node must have identical adapters.

5196-G27 Memory Upgrade Options

The Model G27 engines come equipped with 512 MB of double data rate (DDR) synchronous DRAM (SDRAM) on the engine's planar board. The Model G27 memory contains error correcting code (ECC). The 512 MB memory occupies two of the six memory slots on the planar board. The remaining four memory slots can be populated with additional memory modules up to a total of 4.5 GB base plus added memory features. Each engine must have at least one mandatory optional memory feature installed, either feature number 0301, 1 GB Memory Upgrade or feature number 0302, 2 GB Memory Upgrade. Below are the supported memory options for the Model G27.

5196 Model G27 Supported Memory Options per Engine

 

                                             Total Memory
Memory Feature                Qty            Base + Feature(s)

1 GB Upgrade #0301            1              1.5 GB

1 GB Upgrade #0301            2              2.5 GB

2 GB Upgrade #0302            1              2.5 GB

1 GB Upgrade #0301            1
        +                                    3.5 GB
2 GB Upgrade #0302            1

2 GB Upgrade #0302            2              4.5 GB

Planning Information

Customer Responsibilities: The NAS Gateway 300, 5196 Model G27 is designated as customer setup. Customer setup information and installation instructions are shipped with each system.

Configuration Information

The 5196 Model G27 is designed to be configured and have administrative tasks done from a remote network or management station. Included with these products are the Windows Terminal Service (WTS) and Microsoft Management Console (MMC), which help simplify the configuration and administrative tasks and procedures. These tools are a part of the preloaded OS package residing on the system hard disk and CD-ROM shipped with the systems. The CD-ROM contains client software that is loaded on the remote Network Station™ on the LAN that communicates with the Model G27 to perform configuration and administrator tasks and procedures. Optionally, the IBM Director, running on a network management console on the LAN, can also be used to perform these tasks.

Rack Installations

The NAS 5196 Model G27 requires 5U rack units per engine, and are to be installed in a 19-inch rack cabinet designed for 26-inch deep devices.

If using a non-IBM rack, the cabinet must meet the EIA-310-D standards with a depth of at least 28 inches. Also, adequate space (approximately two inches for the front bezel and one inch for air flow) must be maintained from the slide assembly to the front door of the rack cabinet to allow sufficient space for the door to close and provide adequate air flow.

Power Considerations

The NAS 5196 Model G27 engines have two, 560-watt hot-swappable power supplies, which are redundant for high availability. The power supplies are auto-sensing, auto-ranging, and designed for operation on AC power sources that provide either 90-137 V ac (50-60 Hz) or 180-265 V ac (50-60 Hz).

Power Cords: Power cords for the 5196 Model G27 must be specified when initial orders are placed for the system. Refer to the Hardware Requirements section for a listing of power cords and the applicable (where used) countries.

Network Cables: All network cables that attach the NAS Gateway 300 Model G27 to the Ethernet LAN and the SAN are supplied by the user.

Cable Orders

Cabling Considerations for 10/100 Mbps Ethernet Adapters: The 10/100 Mbps Ethernet Adapters for the NAS Gateway 300 have RJ-45 connectors. The RJ-45 connector provides a 10Base-T or 100Base-TX interface for connecting twisted-pair cable to the Ethernet network. Cabling is not included with the systems or these adapters if ordered as field features. To connect the Ethernet adapters to a repeater or switch, use an unshielded twisted pair (UTP) cable with RJ-45 connectors at both ends. For 100 Mbps operation, Category 5 cabling, or higher must be used. For 10 Mbps operation, Category 3, or higher, cabling must be used.

Cabling Considerations for 10/100/1000 Mbps Ethernet Copper Adapter: The 10/100/1000 Mbps Copper Ethernet Adapter for the NAS Gateway 300 has a RJ-45 connector. The RJ-45 connector provides a 10Base-T/100Base-TX/1000Base-T interface for connecting twisted-pair cable to the Ethernet network. Cabling is not included with the systems or these adapters ordered as field features. To connect the Ethernet adapters to a repeater or switch, use an UTP cable with RJ-45 connectors at both ends. Category 5 cabling, or higher, must be used.

Cabling Considerations for Gigabit SX Ethernet Adapter: The Gigabit SX Ethernet Adapter has a duplex type SC connector for connection of multimode fibre optical cable. This adapter can use either 50 micron or 62.5 micron multimode fiber optic cable. The maximum cable distance for 62.5 micron cable is 275 meters (902 ft). The maximum cable distance with 50 micron cable is 550 meters (1,804 ft).

Cabling Considerations for Fibre Channel Adapters: The 1-port and 2-port Fibre Channel Adapters have compact female type LC duplex connectors for each port. These adapters can use either 50 micron or 62.5 micron type SFP multimode fibre optic cable.

For 50 micron cable:

bulletMaximum cable length is 500 meters at 1 Gbit/s operation.
bulletMaximum cable length is 300 meters at 2 Gbit/s operation.

For 62.5 micron cable:

bulletMaximum cable length is 300 meters at 1 Gbit/s operation.
bulletMaximum cable length is 90 meters at 2 Gbit/s operation.

Security, Auditability, and Control

This product uses the security and auditability features of the application software.

The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities.

Terms and Conditions

This product is available for purchase under the terms of the IBM Customer Agreement (ICA).

IBM hardware products are manufactured from new parts, or new and used parts. In some cases, the hardware product may have been previously installed.

Regardless, IBM warranty terms apply.

Volume orders: Contact your IBM representative.

Warranty Period

bulletThree years for system hardware — Parts
bulletOne year for system hardware — Labor

Licensing: IBM and some non-IBM programs are licensed under the terms and conditions of the IBM License Agreements that ship with the system. IBM also provides programs with this solution that come with their own license agreements. Unless expressly provided by IBM, IBM and non-IBM programs are provided "as is" without warranties of any kind, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose.

Warranty Service: First year: IBM On-Site Repair (IOR) Monday through Friday, 9 hours per day, excluding holidays, next business day response

Second and third years: Parts exchange only

IBM support centers will assist customers with hardware problem isolation to determine if warranty service or parts exchange is required

ServiceSuite™ and ServiceElect (formerly ESA) Maintenance: For ServiceElect (Z125-5510) and ServiceSuite (Z125-5745) Statements of Work

Warranty Service Upgrade

During the warranty period, Warranty Service Upgrade provides an enhanced level of service for an additional charge. This enhanced level of service provides on-site labor during the second and third years, or provides a higher level of on-site service labor in year one, and provides on-site labor during the second and third years. Parts are covered for three years by the original warranty.

The following Warranty Service Upgrade options are available.

bulletIOR, 9 hours a day, Monday through Friday excluding holidays, next business day response

or

bulletIOR, 24 hours a day, 7 days a week, same day response

IBM support centers will assist customers with hardware problem isolation to determine if warranty service or parts exchange is required.

Maintenance Service

Offering 1: IOR, Monday through Friday, 9 hours per day, excluding holidays, next business day response. Customers should call ITS Service (U.S. 800-426-7378).

Offering 2: IOR, 24 hours a day, 7 days a week, same day response. Customers should call ITS Service (U.S. 800-426-7378).

Maintenance Service (ICA)

Currently available maintenance services for existing ICA legacy contracts only. The preferred go-to-market offerings are ServiceElect. However, ICA legacy contracts will still be available for current customers until they are withdrawn.

Alternative Service (Warranty Service Upgrades): During the warranty period, Warranty Service Upgrade provides an enhanced level of service for an additional charge. This enhanced level of service provides on-site labor during the second and third years, or provides a higher level of on-site service labor in year one, and provides on-site labor during the second and third years. Parts are covered for three years by the original warranty.

The following Warranty Service Upgrade options are available.

bulletIOR, 9 hours a day, Monday through Friday excluding holidays, next business day response

or

bulletIOR, 24 hours a day, 7 days a week, same day response

IBM support centers will assist customers with hardware problem isolation to determine if warranty service or parts exchange is required.

Maintenance Service

Option 1: IOR, Monday through Friday, 9 hours per day, excluding holidays, next business day response. Customers should call ITS Service (U.S. 800-426-7378).

Option 2: IOR, 24 hours per day, 7 days per week, same day response. Customers should call ITS Service (U.S. 800-426-7378).

Usage Plan Machine: No

IBM Hourly Service Rate Classification: Two

Mid-Range System Option: Yes

Eligible                      Discount
Types               Three-Year        Five-Year

5187-7RY            12%               17%

Corporate Service Option: Yes

                              Discount
                    Three-Year        Five-Year

System              12%               17%

When a type of service involves the exchange of a machine part, the replacement may not be new, but will be in good working order.

Rental Offering: No

Field-Installable Features: Yes

Model Conversions: No

Machine Installation: Customer Setup. Customers are responsible for installation according to the instructions IBM provides with the machine.

Graduated Charges: No

Educational Allowance: A reduced charge is available to qualified education customers. The educational allowance may not be added to any other discount or allowance.

 

Prices

The prices provided in this announcement are suggested retail prices for the U.S. only and are provided for your information only. Dealer prices may vary, and prices may also vary by country. Prices are subject to change without notice. For additional information and current prices, contact your local IBM representative.

Product Charges

                                    Machine         Feature  Purchase
Description                         Type     Model  Number   Price

NAS 5196 Model G27                  5196     G27             $ 2,500
 (Dual Node)

NAS Engine                          5187     7RY              30,300

                                    Machine         Feature  Purchase
Description                         Type     Model  Number   Price

Optional Features

Gigabit Ethernet Adapter (plt/fld)  5187     7RY    0006     $   800

Remote Supervisor Adapter (plt/fld) 5187     7RY    0010         675

SCSI LVD/SE Adapter (plt/fld)       5187     7RY    0013         405

4-Port 10/100 ENET Adpt  (plt/fld)  5187     7RY    0015       1,560

Remote Spvr Int Cable (plt/fld)     5187     7RY    0016          10

10/100/1000 ENET Adpt (plt/fld)     5187     7RY    0018         250

1 GB Memory Upgrade (plt/fld)       5187     7RY    0301         770

2 GB Memory Upgrade (plt/fld)       5187     7RY    0302       2,075

10/100/1000 Accel ENET (plt/fld)    5187     7RY    3305       1,975

Mirrored OS HDD (plant)             5187     7RY    3121         740

Mirrored OS HDD (field)             5187     7RY    3122         740

36.4 GB SCSI HDD (plt/fld)          5187     7RY    3131         740
 (Spare)

1-Port 2 Gb FC Adapter (plt/fld)    5187     7RY    3705       1,485

2-Port 2 Gb FC Adapter (plt/fld)    5187     7RY    3706       3,560
Specify Features

Power Cord #1 (plt)                 5187     7RY    0101          NC
 U.S. -- Chicago

Power Cord #2 (plt)                 5187     7RY    0102          NC
 Europe, Middle East,
 Africa, others

Power Cord #3 (plt)                 5187     7RY    0103          NC
 Australia,
 New Zealand

Power Cord #4 (plt)                 5187     7RY    0104          NC
 Europe, S. Korea

Power Cord #5 (plt)                 5187     7RY    0105          NC
 Denmark

Power Cord #6 (plt)                 5187     7RY    0106          NC
 Pakistan, S. Africa

Power Cord #7 (plt)                 5187     7RY    0107          NC
 Switzerland,
 Liechtenstein

Power Cord #8 (plt)                 5187     7RY    0108          NC
 Chile, Italy,
 Ethiopia

Power Cord #9 (plt)                 5187     7RY    0109          NC
 Israel

Power Cord #10 (plt)                5187     7RY    0110          NC
 U.S., Japan,
 S. America,

                                    Machine         Feature  Purchase
Description                         Type     Model  Number   Price

Power Cord #11 (plt)                5187     7RY    0111          NC
 Argentina

Power Cord #12 (plt)                5187     7RY    0112          NC
 China

Power Cord #13 (plt)                5187     7RY    0113          NC
 For IBM Rack

Power Cord #14 (plt)                5187     7RY    0114          NC
 U.S., Japan,
 S. America

Preload for 5196-G27 (plt)          5187     7RY    0252          NC

Pubs Group (plt)                    5196     G27    0701          NC

NC = No Charge

 

                                              Field   Plant   MES
                           Machine    Feature Install Install Removal
Description                Type/Model Number  Only    Only

Gigabit Ethernet Adapter   5187-7RY   0006    N       N       N
Remote Supervisor Adapter  5187-7RY   0010    N       N       N
SCSI LVD/SE Adapter        5187-7RY   0013    N       N       N
4-port 10/100 ENET Adpt    5187-7RY   0015    N       N       N
Remote Spvr Int Cable      5187-7RY   0016    N       N       N
10/100/1000 ENET Adpt      5187-7RY   0018    N       N       N
1 GB Memory Upgrade        5187-7RY   0301    N       N       N
2 GB Memory Upgrade        5187-7RY   0302    N       N       N
Mirrored OS HDD            5187-7RY   3121    N       Y       N
Mirrored OS HDD            5187-7RY   3122    Y       N       N
36.4 GB SCSI HDD (spare)   5187-7RY   3131    N       N       N
10/100/1000 Accel ENET     5187-7RY   3305    N       N       N
1-Port 2 Gb FC Adapter     5187-7RY   3705    N       N       N
2-Port 2 Gb FC Adapter     5187-7RY   3706    N       N       N

Power Cords #1             5187-7RY   0101    N       Y       N
Power Cords #2             5187-7RY   0102    N       Y       N
Power Cords #3             5187-7RY   0103    N       Y       N
Power Cords #4             5187-7RY   0104    N       Y       N
Power Cords #5             5187-7RY   0105    N       Y       N
Power Cords #6             5187-7RY   0106    N       Y       N
Power Cords #7             5187-7RY   0107    N       Y       N
Power Cords #8             5187-7RY   0108    N       Y       N
Power Cords #9             5187-7RY   0109    N       Y       N
Power Cords #10            5187-7RY   0110    N       Y       N
Power Cords #11            5187-7RY   0111    N       Y       N
Power Cords #12            5187-7RY   0112    N       Y       N
Power Cords #13            5187-7RY   0113    N       Y       N
Power Cords #14            5187-7RY   0114    N       Y       N
Preload for 5196-G27       5187-7RY   0252    N       Y       N
Pubs Group English         5196-G27   0701    N       Y       N

N = No
Y = Yes

Alternative and Maintenance Service

Alternative Service

Machine                  W95 (Next Day)
Type/Model               IOR, 9 x 5

5187-7RY                 $500

Machine                  W24 (Same Day)
Type/Model               IOR, 24 x 7

5187-7RY                 $1,000

Annual Minimum Maintenance Charges

Machine                  IO8 (Next Day)
Type/Model               IOR, 9 x 5

5187-7RY                 $882

Machine                  IOR (Same Day)
Type/Model               IOR 24 x 7

5187-7RY                 $1,233

Trademarks

 
TotalStorage, ServeRAID, SANergy, Network Station, and ServiceSuite are trademarks of International Business Machines Corporation in the United States or other countries or both.
 
SP2, NetView, AIX, OS/390, and OS/400 are registered trademarks of International Business Machines Corporation in the United States or other countries or both.
 
LANDesk is a trademark of Intel Corporation.
 
Intel is a registered trademark of Intel Corporation.
 
Microsoft is a trademark of Microsoft Corporation.
 
Windows and Windows NT are registered trademarks of Microsoft Corporation.
 
UNIX is a registered trademark of the Open Company in the United States and other countries.
 
Tivoli is a registered trademark of International Business Machines Corporation or Tivoli Systems Inc. in the United States or other countries or both.
 
Notes is a registered trademark of Lotus Development Corporation and/or IBM Corporation.
 
Other company, product, and service names may be trademarks or service marks of others.
Ready to buy
Forward arrow Buy now
 Outside of the U.S.
Forward arrow select a country
Phone call Request a call
 Related information
Forward arrow Product support
Forward arrow Offering data sheet
PDF NAS comparison
Forward arrow IBM NAS interoperability and compatibility
Forward arrow Articles
Forward arrow Resource library



 

 
 

  About US  |  Privacy  |  Legal  |  Contact  

Send mail to webmaster@c-pro.com with questions or comments about this web site.
Copyright © 2003 Computer PRO                   Last modified: 03/05/03